CMB-153-11C3N-B-A [Carling Technologies]

Thermal Circuit Breaker;
CMB-153-11C3N-B-A
型号: CMB-153-11C3N-B-A
厂家: Carling Technologies    Carling Technologies
描述:

Thermal Circuit Breaker

电路保护
文件: 总4页 (文件大小:931K)
中文:  中文翻译
下载:  下载PDF数据表文档文件
CMB  
CMB-  
Series  
THERMAL CIRCUIT PROTECTORS  
The CMB-Series is a compact, single pole, push-to-reset family of thermal circuit breakers designed to protect  
equipment. Utilizing simple, precision design with few moving parts, these breakers offer cost effective,  
extremely reliable circuit protection with high resistance against shock and vibration.  
Product Highlights:  
Ratings from 3-20A, 125, 250VAC, 32VDC  
Applications:  
Household Appliances  
Š
Š
Š
Š
2500 VAC/1 minute  
Transportation  
Š
Š
60°C Max Operating Temperature  
Marine  
Š
Š
2500A @ 32VDC Interrupting Capacity  
Power Strips  
Š
Š
100M ohms Insulation Resistance  
Medical Equipment  
Š
Š
Voltage drop <0.25 V  
Audio Visual Equipment  
Š
Š
UL, cUL, CSA, TUV, CE  
Power Supplies  
Š
Š
UL1500/ISO8846 for ignition protection/marine  
ROHS Complaint  
Dimensional Specifications: in. [mm]  
Carling Technologies, Inc.  
60 Johnson Avenue, Plainville, CT 06062  
Email: sales@carlingtech.com  
Application Support: team2@carlingtech.com  
Phone: 860.793.9281 Fax: 860.793.9231  
www.carlingtech.com  
|
2
CMB-Series - Ordering Scheme, Time Delay, Dimensional Specifications  
CMB 10 3 11 C 3 N B A /10  
5
6
7
8
9
10  
1
2
3
4
Bushing  
Type  
Mounting Indicator  
Nut Plate  
Button  
Terminal  
Button Marking  
Series  
Rating  
Voltage  
Mounting  
Hole  
1 SERIES  
CMB  
3 VOLTAGE  
3
125-250VAC/ 32 VDC  
4 MOUNTING HOLE  
2 RATING  
10  
12  
13  
14  
15  
16  
20  
10 amps  
1
11  
12  
00  
27  
28  
M11  
03  
04  
05  
06  
07  
08  
3 amps  
12 amps  
13 amps  
14 amps  
15 amps  
16 amps  
20 amps  
2
3
15  
12  
M12  
4 amps  
5 amps  
6 amps  
7 amps  
8 amps  
Snap In Style  
3/8” 27 UNS  
3/8” 27 UNS  
(double flatted)  
5 BUSHING  
PLASTIC  
4
4
5
8
6
C
D
E
G
H
K
Type C  
Type D  
Type E  
Type G  
Type H  
Type K  
13  
METAL  
8
J
Type J  
7
6 MOUNTING NUT  
N
1
2
3
4
5
6
7
8
None  
Type 1  
Type 2  
Type 3  
Type 4  
Type 5  
Type 6  
Type 7  
Type 8  
11  
14  
9
9
NOTE: Type 5 is clear hex boot. Type 8 is black hex boot (available for bushings G, J & K only); Type 3 nut includes molded in “PRESS TO RESET” marking.  
Notes: All dimensions are in.[mm]. Tolerance ±.005 [.127] unless otherwise specified.  
7
Embossed  
Silver Printing  
On Black  
7 INDICATOR PLATE  
(ALUMINUM)  
N
A
B
None  
1
2
3
4
5
6
7
Used with bushing C or D only.  
Used with H bushing only.  
10 Amp rating must match button marking  
(ex: 20 will be marked on the button of  
CMB-203-27G3N-W-A/20)  
Embossed Legend  
Silver Printing  
on Black  
.887  
[22.5]  
.887  
[22.5]  
.016  
[.4]  
.016  
[.4]  
Used with bushing E only.  
Used with M11 mounting hole only.  
Used with mounting hole 00 only.  
Used with M12 mounting hole only.  
All hardware available separately.  
Consult factory.  
11 Includes molded in “PRESS TO RESET”  
marking.  
12 Available with K bushing only.  
13 Available with mounting hole 28 only.  
14 Thickness is 3.0 mm, .118 in.  
15 Available with G or J bushing only.  
All indicator plates are marked  
“Suppl. Prot. press to reset”.  
8
9
Available with mounting hole 27 only.  
Available with G, J or K bushing only.  
8 BUTTON  
B
Black  
R
Red  
W
White  
9 TERMINAL  
A
B
C
D
E
Type A  
Type B  
Type C  
Type D  
Type E  
F
Type F  
Type G  
Type H  
Type J  
Type R  
G
H
J
R
R
F,G,H,J TERMINALS ARE 8-32 UNC  
without screw  
10  
line  
load  
10 BUTTON MARKING (IF BLANK, NO MARKING)  
Button Marking Orientation:  
20  
03  
04  
3 amp  
4 amp  
05  
06  
5 amp  
6 amp  
07  
08  
7 amp  
8 amp  
10  
12  
10 amp  
12 amp  
13  
14  
13 amp  
14 amp  
15  
16  
15 amp  
16 amp  
20  
20 amp  
Time Delay  
Notes:  
1.  
Overload  
Trip Time  
No Trip  
Trip in 1 hr  
4.0 ~ 40 sec.  
0.9 ~ 8.0 sec.  
Time Trip Factor 1  
-10 °C x 1.70  
Time Trip Factor 1  
Trip Time factor  
30 °C x 0.90  
35 °C x 0.85  
40 °C x 0.80  
45 °C x 0.75  
50 °C x 0.70  
55 °C x 0.65  
60 °C x 0.60  
100%  
150%  
200%  
300%  
is a guideline that  
indicates ambient  
temperature effect on  
trip times at various  
overload values.  
-5 °C  
0 °C  
5 °C  
x 1.60  
x 1.50  
x 1.40  
400% 0.42 ~ 5.0 sec.  
500% 0.25 ~ 3.0 sec.  
600% 0.01 ~ 1.8 sec.  
10 °C x 1.30  
15 °C x 1.20  
20 °C x 1.10  
25 °C x 1.00  
ꢎꢂꢏꢐ ꢎꢏꢑꢁ ꢏꢄ ꢒꢁꢃꢈꢄꢋꢓ  
*Manufacturer reserves the right to change product specification without prior notice.  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
|
Sales Representatives, Distributors & Company Profile  
3
Authorized Sales Representatives and Distributors  
Click on a region of the map below to find your local representatives and distributors or visit  
www.carlingtech.com/findarep.  
CANADA  
EUROPE  
USA  
MIDDLE  
EAST  
MEXICO  
AFRICA  
ASIA-PACIFIC  
OCEANIA  
SOUTH  
AMERICA  
About Carling  
Founded in 1920, Carling Technologies is a leading manufacturer of electrical and electronic switches  
and assemblies, circuit breakers, electronic controls, power distribution units, and multiplexed power  
distribution systems. With four ISO registered manufacturing facilities and technical sales offices worldwide,  
Carling Technologies Sales, Service and Engineering teams do much more than manufacture electrical  
components, they engineer powerful solutions! To learn more about Carling please visit  
www.carlingtech.com/company-profile.  
To view all of Carling’s environmental, quality, health & safety certifications please visit  
www.carlingtech.com/environmental-certifications  
Email: sales@carlingtech.com Application Support: team2@carlingtech.com  
Phone: (860) 793–9281 Fax: (860) 793–9231 www.carlingtech.com  
Worldwide Headquarters  
Carling Technologies, Inc.  
60 Johnson Avenue, Plainville, CT 06062  
Phone: 860.793.9281 Fax: 860.793.9231  
@
Email: sales carlingtech.com  
@
Northern Region Sales Office: nrsm carlingtech.com  
@
Southeast Region Sales Office: sersm carlingtech.com  
@
Midwest Region Sales Office: mrsm carlingtech.com  
@
West Region Sales Office: wrsm carlingtech.com  
@
Latin America Sales Office: larsm carlingtech.com  
Asia-Pacific Headquarters  
Carling Technologies, Asia-Pacific Ltd.,  
Suite 1607, 16/F Tower 2, The Gateway,  
Harbour City, 25 Canton Road,  
Tsimshatsui, Kowloon, Hong Kong  
Phone: Int + 852-2737-2277 Fax: Int + 852-2736-9332  
@
Email: sales carlingtech.com.hk  
@
Shenzhen, China: shenzhen carlingtech.com  
@
Shanghai, China: shanghai carlingtech.com  
@
Pune, India: india carlingtech.com  
@
Kaohsiung, Taiwan: taiwan carlingtech.com  
@
Yokohama, Japan: japan carlingtech.com  
|
|
Europe Middle East Africa Headquarters  
Carling Technologies LTD  
4 Airport Business Park, Exeter Airport,  
Clyst Honiton, Exeter, Devon, EX5 2UL, UK  
Phone: Int + 44 1392.364422 Fax: Int + 44 1392.364477  
@
Email: ltd.sales carlingtech.com  
@
Germany: gmbh carlingtech.com  
@
France: sas carlingtech.com  
www.carlingtech.com  
REV_11_2016  

相关型号:

CMB-153-11D2B-B-H

Thermal Circuit Breaker
Carling Techn

CMB-153-27G3N-B-A

Thermal Circuit Breaker
Carling Techn

CMB-153-27GNN-W-A

Thermal Circuit Breaker
Carling Techn

CMB-153-27J1A-R-C/15

Thermal Circuit Breaker
Carling Techn

CMB-153-28K1A-B-A/15

Thermal Circuit Breaker
Carling Techn

CMB-153-28K1B-B-J/15

Thermal Circuit Breaker
Carling Techn

CMB-163-00E1B-R-E/16

Thermal Circuit Breaker
Carling Techn

CMB-163-00E2N-R-B/16

Thermal Circuit Breaker
Carling Techn

CMB-163-00E3A-W-A/16

Thermal Circuit Breaker
Carling Techn

CMB-163-00E3B-W-J/16

Thermal Circuit Breaker
Carling Techn

CMB-163-00E4A-B-H/16

Thermal Circuit Breaker
Carling Techn

CMB-163-00ENA-R-G/16

Thermal Circuit Breaker
Carling Techn